| Finish | Zinc | Aluminum die cast | Notes |
|---|---|---|---|
| Electroplating (Cu/Ni/Cr) | Excellent — the standard route | Possible but demanding; rarely chosen | Zinc takes a true mirror finish. Aluminum's silicon content makes pretreatment fussy and consistency poor. |
| Electroless nickel | Good | Good | Even coverage including internal surfaces; common for EMI continuity on housings. |
| Powder coating | Workable | Excellent | Thick (60–120 µm), hides surface detail, good corrosion barrier. Needs a conductive substrate and a temperature the part can survive. |
| Wet paint | Good | Good | Thinner (20–40 µm), cheaper at low volume, more colour flexibility for small batches. |
| Anodising | Not applicable | Not cosmetic on high-silicon die cast | See §5 — the silicon does not anodise, so the result is dark and blotchy. |
| Bead blasting / tumbling | Good | Good | A preparation step or a final finish for industrial parts. Uniformity depends on part geometry. |
| Passivation / conversion coat | Good | Good | Bare corrosion protection and a paint base. Not decorative. |
| Bare, as-cast | Poor outdoors | Moderate outdoors | Zinc oxidises to a white corrosion product; aluminum forms a protective oxide but stains. |
A chrome-plated zinc casting is not simply "dipped". The sequence is: polishing to remove casting skin and flow marks → degreasing → acid activation → copper strike → copper build → nickel → chromium. Each layer has a purpose, and each one can fail independently.
The practical consequence: plating quality is decided by the polish, not by the plating bath. A casting with flow marks, cold shuts or visible porosity will show every one of them after plating, magnified. This is why plating and casting cannot be sourced separately without an argument over who owns the defect.
| Layer | Typical thickness | What happens if too thin | What happens if too thick |
|---|---|---|---|
| Copper | 15–30 µm | Cannot level the casting surface; roughness telegraphs through | Cost, and stress build-up causing blistering |
| Nickel | 10–20 µm | Corrosion resistance and salt spray hours drop sharply | Internal stress, cracking on flexing parts |
| Chromium | 0.1–0.5 µm | Wear resistance and colour depth lost | Micro-cracking, and a bluish cast on some baths |
When a customer specifies "chrome plated", ask for the layer stack and thicknesses. A supplier who cannot state them is either subcontracting without specification or does not know — and either way the salt spray result will be a surprise.
Both processes need a clean, conductive, slightly rough surface. Die castings give you three challenges:
Powder coating is thicker and more durable but hides fine detail and needs a cure temperature — check the alloy and any plastic inserts first. Wet paint is thinner and cheaper for small batches, and lets you match a colour more easily.
The result is not a cosmetic finish. On a hidden internal part it may be acceptable as a corrosion measure; on a visible housing it is a reject.
If a specification genuinely requires anodised aluminum, the part usually needs to be extruded or machined from a low-silicon wrought alloy (6061, 6063), not die cast. That is a different manufacturing route with a different cost structure. It should be identified at the quoting stage, not after the tool is cut.
Castings are made in-house; plating and anodising run through qualified partners against our specification, and we inspect the finished parts before they ship. That means one commercial counterparty for you and one technical owner for the process chain — if a lot fails salt spray, the argument happens inside our supply chain rather than across yours.
We ship the finish test data with the lot: layer thickness readings and the salt spray or adhesion result, as applicable. If a customer's specification requires a particular standard or a particular laboratory, tell us at the quote stage so it is priced and planned rather than discovered at shipment.